Project Description
Fluxer M Series 25KVA ~ 125KVA
Fluxer M Series (25kVA ~ 125kVA) UPS is a high-end modular UPS with latest DSP control technology and most reliable, famous brand components.
It adopts a highly intelligent modular design, which mainly contains power modules, bypass module and control module,all modules support “plug & play” to simplify UPS servicing and maintenance.
The available UPS power and redundancy level can expand vertically from 25 kVA / 25 kW to 125 kVA / 125 KW in one single power cabinet with flexible configuration for meeting different needs.
Based on superior electrical performance, perfect hardware and software protection function, Fluxer M Series UPS can adapt to different grid environment and provides maximum protection and high quality power for critical loads in data centers or other important applications.
Characteristics
- DSP microprocessor control technology
- True On-line, double conversion power protection, and with strong load capacity
- Modular Hot-swappable design for easy maintenance and scalability
- High efficiency up to 96.5% at most frequently-used load rate
- Inbuilt integrated PDU system simplifying installation and saving investment
- Output power factor 1.0, input power factor 0.99, input THDi<3%, output THDv≤ 1%
- 138 ~ 485 Vac wide input voltage range, 50 Hz / 60 Hz grid self-adaptive
- Soft-start technology improves generator matching up to 1:1.1
- Support two modes of frequency conversion: 50 Hz input / 60 Hz output and 60 Hz input / 50 Hz output
- Intelligent hibernation mode upgrading enables UPS to operate efficiently at low load rate
- Advanced parallel and redundancy technology, support 4 units connected in parallel
- Share battery pack in parallel operation, saving user’s battery cost
- Flexible charger parameter and battery configuration settings, battery number 30 ~ 46 pcs selectable
- Intelligent battery management technology (Intelligent charge/discharge management and float charging voltage temperature compensation), extending battery lifespan
- Support cold start with battery and auto restart with mains power
- Self-aging function to simplify debugging and test on site
- Fault-tolerant design for fan system, taking 30% loads when 2 fans fail and 50% loads when 1 fan fails
- Superior hardware and software protection function, robust self-diagnostic function, and abundant event log for check
- 7 inches LCD touch screen, friendly human-machine interface
- System with built-in SNMP, supporting RS485 and dry contacts
- Back-feed protection function (optional)
Technical Specifications
| MODEL |
FLUM125T5T0 |
| Rated capacity of system cabinet | 125kVA |
| Number of power module | 5 |
| Rated capacity of power module | 25kVA |
| INPUT | |
| Input wiring | Three-phase five-wire (3φ+N+PE) |
| Rated voltage | 380Vac/400Vac/415Vac |
| Voltage range | 135 ~ 305Vac (linear derating), 305 ~ 485Vac (no derating) |
| Frequency range | 40~70Hz |
| Input power factor | Full load> 0.99; half load> 0.98 |
| THDi | < 3% (linear full load); < 5% (non-linear full load) |
| Battery voltage | ±240VDC (±180, ±192, ±204, ±216, ±228, ±252, ±264, ±276, selectable) |
| Number of battery | 40 pcs 12 V batteries (30, 32, 34, 36, 38, 42, 44, 46 pcs selectable) |
| OUTPUT | |
| Output wiring | Three-phase five-wire (3φ+N+PE) |
| Rated voltage | 380 Vac / 400 Vac / 415 Vac |
| Output voltage regulation accuracy | ±1% |
| Output frequency accuracy | Synchronized with utility in mains power mode; 50 Hz / 60 Hz ± 0.05% in battery mode; |
| Output power factor | 1 |
| Output waveform distortion (THDv) | ≤ 1% (linear load); ≤ 4% (Non-linear load) |
| Crest factor | 3:1 |
| Inverter overload capacity | 105% < load ≤ 110%: transfer to bypass in 60 mins 110% < load ≤ 125%: transfer to bypass in 10 mins 125% < load ≤ 150%: transfer to bypass in 1 min Load > 150%: transfer to bypass in 300 ms |
| Bypass overload capacity | Temperature≤30℃, load ≤135% for long term; temperature≤40℃, load ≤125% for long term; load >1000% for 0.1 s |
| SYSTEM | |
| Efficiency | Up to 96% |
| Max. number of parallels | 4 |
| Transfer time | 0ms |
| Protection | Lack-phase protection, phase sequence error protection, short circuit protection, overload protection, over-temperature protection, battery low voltage protection, output undervoltage protection, fans failure protection etc. |
| Communications | RS485, dry contacts, SNMP |
| Display | 7 inches LCD touch screen |
| ENVIRONMENT | |
| Operating temperature | 0℃~ 40℃ |
| Storage temperature | –40℃ ~ +70℃ |
| Relative humidity | 0% RH ~ 95% RH (non-condensing) |
| Altitude | 0 m ~ ≤1000 m, above 1000 m, derating 1% for each additional 100 m |
| Protection level | IP 20 |
| Noise | ≤65 dB (at 1 m) |
| OTHERS | |
| Cabinet dimensions (WxDxH) (mm) | 600x850x2000 |
| Module dimensions (WxDxH) (mm) | 442x620x86 |
| Cabinet weight (kg) | 182.7 |
| Power module weight (kg) | 19.1 |