Project Description
Fluxer T Series 10~15KVA (208V)
Code: FLUT010T3T0, FLUT015T3T0
Fluxer T Series 10~15KVA (3:3) online UPS is an on-line double-conversion UPS with input power factor correction (PFC), output power factor 1.0 offering high levels of reliability and protection for critical servers and data processing IT systems.
Characteristics
- DSP digital control technology
- Active power factor correction (APFC), input power factor up to 0.99
- Output power factor 1.0
- Cold start
- Dual input
- Wide input voltage range (121 V ~ 277 V)
- Auto sensing frequency
- 50 / 60 Hz frequency conversion mode
- Work efficiency up to 97% in ECO mode
- Auto control fan speed when loads varies
- Auto power ON / OFF according to the load capacity set by users
- Flexible battery configuration for using 14 / 16 / 18 / 20 pcs batteries
- Compact internal layout miniaturizes the complete unit for small footprint
- 5″ colorful touchscreen display, friendly human-machine interface
- Powerful background software for parameters configuration and online updating
- Doubling the battery charging speed, 90% capacity restored in 4 hours (standard model UPS)
- Linear derating in low voltage input reducing battery discharging times
- Advanced battery management (ABM), automatic floating / equalizing charge control, charge dormancy control
- Configurable switching time from battery mode to mains mode when mains power is restored
- Effective software and hardware protection function, powerful self-diagnostic function, abundant historical records
- Standard emergency power off (EPO)
- Standard maintenance bypass
- Standard RS232 / USB communication port
- Optional RS485 / SNMP / AS400 communication port and SMS alarms
- Optional N+X redundancy parallel up to 6 units
- Optional battery temperature compensation, EMD environmental sensors
Technical Specifications
MODEL |
FLUT010T3T0 |
FLUT015T3T0 |
|
Capacity |
10 kVA / |
15 kVA / 15 kW |
|
INPUT |
|||
Rated voltage |
173 Vac / 190 Vac / 200 Vac / 208 V |
||
Voltage range |
156 ~ 277 Vac (no derating); 121 ~ 156 Vac (linear derating |
||
Rated frequency |
50 / 60 Hz (auto-sense) |
||
Frequency range |
40 |
||
Power factor |
≥ 0.99 |
||
Total harmonic distortion (THDi) |
≤ |
||
Bypass voltage range |
-40% |
||
OUTPUT |
|||
Voltage |
173 Vac / 190 Vac / 200 Vac / 208 Vac / 220 Vac (settable) |
||
Voltage regulation |
± 1% |
||
Frequency |
45 |
||
Waveform |
Sinusoidal |
||
Crest factor |
3:1 |
||
Total |
≤ 2% (linear load); ≤ 5% (non-linear |
||
Transfer time |
Mains |
||
Inverter overload capability |
102% 125% > |
||
Bypass overload capability |
102% 125% > |
||
BATTERIES |
|||
DC |
Standard model: 240 VDC; Long |
||
Inbuilt battery of standard model |
20 |
40 |
|
Recharge time |
Standard Long |
||
SYSTEM |
|||
Efficiency |
≥ |
||
Display |
5” colorful |
||
Alarm |
Battery |
||
Max. parallel numbers |
6 |
||
EMI |
IEC / EN62040-2 |
||
EMS |
IEC61000-4-2 (ESD) |
||
IEC61000-4-3 (RS) |
|||
IEC61000-4-4 (EFT) |
|||
IEC61000-4-5 (surge) |
|||
COMMUNICATIONS |
|||
RS232 / USB / RS485 / dry contacts |
Supports |
||
SNMP |
Power |
||
OTHERS |
|
||
Humidity |
20 |
||
Noise level |
≤ |
||
Dimensions (W×D×H) (mm) |
350 × 655 × 732 (H) |
||
350 × 785 × 1078 (S) |
|||
Packaged dimensions (W×D×H) (mm) |
472 |
||
472 |
|||
Net weight (kg) |
61 (H), 125 (S) |
65 (H), 175 (S) |
|
Gross |
71 (H), 140 (S) |
75 (H), 200 (S) |
|