Project Description
Fluxer T Series 150KVA ~ 800KVA
Fluxer T Series 150KVA ~ 800KVA is three-phase input and three-phase output uninterruptible power supply system with high frequency on-line double-conversion technology controlled by DSP (Digital Signal Processor) microprocessor.
It adopts a highly intelligent modular design to achieve utmost compact layout and improve reliability of the system. It meets the protection demands of critical loads in data centres or other improtant appications with high electrical performance and hardware/software protections.
Characteristics
- DSP digital control technology
- Pure sine wave double conversion, with strong load capacity
- Modular design, high reliability and easy maintenance
- Dual input power distribution for higher usability
- Input power factor > 0.99, THDi < 3%, environment friendly and high-efficiency and energy-saving
- Keep high efficiency operation at low load rate: 96% at 40% rated load and 95% at 20% rated load
- High power density, 500KVA system only 1.02 m2 footprint
- High Efficiency operating in on-line mode up to 96%, in ECO mode up to 99%
- Wide input voltage range, 50Hz/60Hz frequency anto-sense, adapt to all kind of grid
- Support two modes of frequency conversion: 50Hz input/60Hz output and 60Hz/input 50Hz output
- Output power factor 0.9, load capability improved 12.5% more than traditional products
- Advanced parallel expansion technology, support 4 units in parallel
- Share battery pack in parallel operation, saving user’s battery cost
- Flexible charger parameter and battery configuration setting, battery number 30 ~ 46pcs selectable
- Intelligent battery management (Intelligent charge/discharge management and float charging voltage temperature compensation), extending battery lifespan
- Support battery cold start and utility self boot
- Self-aging function, easy debugging and test on site
- Complete hardware and software protection function, robust self-diagnostic function, and abundant event log for check
- 7 inches LCD touch screen, friendly human-machine interface
- Monitoring unit with built-in SNMP, supports RS485 and dry contacts
Technical Specifications
MODEL |
FLUT150T5T0 |
FLUT200T5T0 |
FLUT300T5T0 |
FLUT400T5T0 |
FLUT500T5T0 |
FLUT600T5T0 |
FLUT800T5T0 |
Rated capacity |
150KVA / 135 KW |
200KVA / 180 KW |
300KVA / 270 KW |
400KVA / 360 KW |
500KVA / 450 KW |
600KVA / 540 KW |
800KVA / 640 KW |
INPUT | |||||||
Input wiring |
3Ph+N+PE |
||||||
Rated voltage |
380/400/415Vac |
||||||
Voltage range |
138 ~ 485 Vac (305 ~ 485 Vac without power downgrading; |
||||||
Input frequency |
40~ 70Hz |
||||||
Power factor |
≥0.99 |
||||||
Current distortion |
<3% |
||||||
BATTERIES | |||||||
Battery voltage |
± 240 Vdc (±180, ± 192, ± 204, ± 216, ± 228, ± 252, ± 264, ± 276 selectable) |
||||||
Number of battery |
40 pcs12V batteries ( supports 30 / 32 / 34 / 36 / 38 / 42 / 44 / 46 pcs) |
||||||
OUTPUT | |||||||
Output wiring |
3Ph+N+PE |
||||||
Rated voltage |
380/400/415Vac |
||||||
Voltage regulation accuracy |
± 1% |
||||||
Frequency |
Synchronized with utility in mains power mode: |
||||||
Power factor |
0.9 |
||||||
Voltage distortion |
≤1% with liner load / ≤3% with non-linear load |
||||||
Crest factor |
3:1 |
||||||
Inverter overload capacity |
105% < load ≤ 110%: transfer to bypass in 60 min 110% < load ≤ 125%: transfer to bypass in 10 min 125% < load ≤ 150%: transfer to bypass in 1 min Load > 150%: transfer to bypass in 200 ms |
||||||
Bypass overload capacity |
Load ≤135% for long term; <1000% load for 100 ms |
||||||
SYSTEM | |||||||
Efficiency |
96% |
||||||
Max. number of parallel |
4 units |
||||||
Transfer time |
0ms |
||||||
Protection |
Lack-phase protection, phase-error protection, short circuit protection, overload protection, over-temperature protection, battery low voltage protection, output over/low voltage protection, fans failure protection ect. |
||||||
Communications |
RS485, dry contacts, SNMP |
||||||
Display |
7 inches LCD touch screen |
||||||
OTHERS | |||||||
Operating temperature |
0 ~ 40℃ |
||||||
Storage temperature |
-40℃ ~ 70℃ |
||||||
Humidity |
0 ~ 95%(non-condensing) |
||||||
Altitude |
≤1000m. Above 1000m, derating 1% for each additional 100 m |
||||||
Protection level |
IP20 |
||||||
Noiselevel at 1 m |
<65 dB |
<68 dB |
|||||
Cabinet dimensions (WxDxH) (mm) |
600×850×2000 |
1200×850×2000 |
1400×850×2000 |
2400×850×2000 |
|||
Weight (kg) |
333 |
365 |
439 |
680 |
795 |
1011 |
1540 |