Fluxer I Series 400~2000VA
From 400VA to 2000VA line interactive UPS, is typically used to protect and power certain equipment, such as personal computers, small scale exchange, POS machines etc.
It provides comprehensive power protection against surges and spikes, and also provides pure voltage with boost and buck AVR.
It power equipment sufficient runtime without any objectionable dip or brownout to that device; and it is the simplicity and low costs. Installation is easy and quick.
Characteristics
- LED display or LCD display selectable
- Microprocessor-based digital control
- Boost and buck AVR for voltage stabilization
- Auto sensing frequency
- Wide input voltage range
- Power-on self test
- Cold start
- Auto restart when mains power is restored
- Auto track mains phase to ensure that inverter output voltage has same phase with utility voltage, reducing transfer time and peak surge
- Intelligent battery management: battery temperature compensation to extend the battery life; three-stage charging to shorten recharge time
- Short circuit, battery overcharge / overdischarge, overload, surge protections
- Automatic charging in OFF mode
- Optional no-load shutdown
- Optional RS232 / USB communication port and RJ11 / RJ45 protection
- Unattended safety shutdown: system alarm and auto Power-On / Off by RS232 or USB interface communicating with PC
Technical Specifications
MODEL | FLUI004T2IS | FLUI006T2IS | FLUI008T2IS | FLUI012T2IS | FLUI015T2IS | FLUI020T2IS | |
Capacity | 400 VA | 600 VA | 800 VA | 1200 VA | 1500 VA | 2000 VA | |
240 W | 360 W | 480 W | 720 W | 900 W | 1200 W | ||
INPUT | |||||||
Voltage | 100 V / 110 V / 120 V: 80 ~ 150 Vac; | ||||||
220 V / 230 V / 240 V: 162 ~ 295 Vac (220 V: 145 | |||||||
~ 295 Vac optional) | |||||||
Frequency | 50 / 60 Hz ± 10% (auto-sense) | ||||||
OUTPUT | |||||||
Voltage | 100 V / 110 V / 120 Vac ± 10% or 220 V / 230 V / 240 Vac ± 10% | ||||||
Frequency | 50 / 60 Hz ± 1% (auto-sense) | ||||||
Waveform | Mains mode: pure sine wave ; Battery mode: simulated sine wave | ||||||
Transfer time | 2 ~ 7 ms (typical), 10 ms (max.) | ||||||
BATTERIES | |||||||
DC voltage | 12 V | 24 V | |||||
Configuration | 12 V / 4.5 Ah × 1 | 12 V / 7.0 Ah × 1 | 12 V / 8.0 Ah × 1 | 12 V / 7.0 Ah × 2 | 12V / 8.0 Ah× 2 | 12 V / 9.0 Ah× 2 | |
Recharge time | 6 ~ 8 h | ||||||
COMMUNICATIONS | |||||||
USB / RS232 / SNMP (optional) | Support Windows® 98 / 2000 / 2003 / XP / Vista / 2008 / Windows®7 / 8 / 10 | ||||||
OTHERS | |||||||
Protections | Short circuit – battery overcharge – overdischarge – overload – surge | ||||||
Humidity | 20 ~ 90% RH @ 0 ~ 40℃ (non-condensing) | ||||||
Noise level | ≤ 45 dB (1m) | ||||||
Plastic case | Net / Gross weight (kg) | 3.8 / 4.3 | 4.3 / 4.8 | 5.3 / 5.8 | 9.5 / 10.0 | 10.7 / 11.2 | — |
Dimensions (W×D×H) (mm) | 100×280×140 | 140×345×170 | — | ||||
Packaged dimensions (W×D×H) (mm) | 139×325×210 | 198×406×245 | — | ||||
Quantity / 20ft | 2300 pcs | 1000 pcs | — | ||||
Metal case | Net / Gross weight (kg) | — | 5.5 / 6.0 | 6.7 / 7.2 | 10.5 / 11.2 | 12.6 / 13.4 | 14.0 / 14.8 |
Dimensions (W×D×H) (mm) | — | 95×320×160 | 125×320×225 | 125×380×225 | |||
Packaged dimensions (W×D×H) (mm) | — | 145×375×230 | 180×390×295 | 180×450×295 | |||
Quantity / 20ft | — | 2000 pcs | 1000 pcs | ||||
Rack mount | Net / Gross weight (kg) | — | 7.8 / 8.3 | 9.0 / 9.5 | 12.6 / 13.2 | 15.7 / 16.3 | 17.0 / 17.6 |
Dimensions (W×D×H) (mm) | — | 308×438×88 | 308×438×132 | ||||
Packaged dimensions (W×D×H) (mm) | — | 395×525×185 | 395×525×2 |